LSI LSI20320 User Manual

LSI LSI20320 User Manual

Ultra320 scsi host adapters
Hide thumbs Also See for LSI20320:
Table of Contents

Advertisement

USER'S
GUIDE
Ultra320 SCSI
Host Adapters
S e p t e m b e r 2 0 0 6
Version 2.3
®
DB15-000192-04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LSI20320 and is the answer not in the manual?

Questions and answers

Summary of Contents for LSI LSI20320

  • Page 1 USER’S GUIDE Ultra320 SCSI Host Adapters S e p t e m b e r 2 0 0 6 Version 2.3 ® DB15-000192-04...
  • Page 2 Shielded cables for SCSI connection external to the cabinet are used in the compliance testing of this Product. LSI Logic is not responsible for any radio or television interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by LSI Logic.
  • Page 3 LSI Logic; nor does the purchase or use of a product from LSI Logic convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of LSI Logic or third parties.
  • Page 4 Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 5 Preface This document is the user’s guide for all LSI Logic Ultra320 SCSI Host Adapters. It contains a functional description of the Ultra320 SCSI host adapters as well as physical and electrical specifications. It also contains instructions for installing the host adapters and for connecting SCSI devices to them.
  • Page 6 July 2003 minor editing also. In Section 3.3.2, corrected storage temp ° ° range to −40 C to 105 DB15-000192-00 Version 2.0 Final version. May 2002 Preface Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 7: Table Of Contents

    Completing the Installation 2-13 Setting Up Integrated RAID (IR) Solution 2-13 2.7.1 Integrated Mirroring Solution 2-14 2.7.2 Integrated Striping Solution 2-14 Ultra320 SCSI Host Adapters User’s Guide Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 8 3-14 Technical Specifications 3-14 3.3.1 Electrical Characteristics 3-14 3.3.2 Thermal and Atmospheric Characteristics 3-15 3.3.3 Safety Characteristics 3-16 Appendix A Glossary of Terms Customer Feedback viii Contents Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 9 LSI20320IE and LSI21320ILE Host Adapter Drawing LSI21320 and LSI21320-R Host Adapter Drawing LSI22320 and LSI22320-R Host Adapter Drawing 3-11 LSI22320T Host Adapter Drawing 3-11 LSI22320SE and LSI22320SLE Host Adapter Drawing 3-13 Contents Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 10 Contents Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 11 SCSI ID Record for Dual Channel Host Adapter 2-12 Host Adapter Installation Checklist 2-13 Ultra320 SCSI to PCI/PCI-X or PCI Express x4 Host Adapters Host Adapter Characteristics 3-14 Maximum Power Requirements 3-15 Contents Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 12 Contents Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 13: Quick Installation Procedures

    Host Adapters LSI53C1020 LSI20320, LSI20320-R, LSI20320L-R LSI53C1020A LSIU320, LSIU320-R, LSI20320A, LSI20320A-R LSI20320IE, LSI20320ILE LSI53C1030 LSI21320, LSI21320-R, LSI22320, LSI22320-R, LSI22320SE, LSI22320SLE LSI53C1030T LSI22320T Ultra320 SCSI Host Adapters User’s Guide Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 14: Quick Host Adapter Installation

    Failure to do so may result in exposure to shock, electrical hazards, and/or mechanical hazards. Step 2. Open your computer cabinet by removing its cover. Quick Installation Procedures Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 15 Step 13. Plug in all power cords and turn on power to all devices and your computer. Step 14. Wait for your computer to start up. The host adapter installation is complete. Quick Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 16: Quick Windows Driver Installation

    Service Packs 5 or higher after Windows NT 4.0 has been installed. Note: Refer to the Fusion-MPT Device Management User’s Guide for detailed configuration and installation instructions for all firmware and drivers. Quick Installation Procedures Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 17: Detailed Host Adapter Installation

    Be sure to disconnect the computer’s power before you remove the cover and install the Ultra320 SCSI host adapter. Step 2. Open your computer cabinet by removing its cover. Ultra320 SCSI Host Adapters User’s Guide Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 18: Hardware Connections For The Host Adapter

    You can insert a 64-bit host adapter into a 32-bit slot if no 64-bit slots are available. However, this limits the data transmission rate to 32-bit transfers. Detailed Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 19: Inserting The Host Adapter

    Inserting the Host Adapter Bracket Screw Press Here Press Here PCI Connectors PCI Express Edge of Connector x16 Motherboard PCI Express Connector x4 Installing Your Ultra320 SCSI Host Adapter Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 20: Scsi Device Cables

    SCSI cables with and without a terminator. Figure 2.3 SCSI Cable – 68-Pin High Density with Terminator Terminator Figure 2.4 SCSI Cable – 68-Pin High Density without Terminator Detailed Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 21: External Scsi Cable

    SCSI Cable – 68-Pin VHDCI to 68-Pin VHDCI Figure 2.6 SCSI Cable – 68-Pin VHDCI to 68-Pin HD Figure 2.7 SCSI Cable – 68-Pin HD to 68-Pin HD SCSI Device Cables Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 22: Connecting Scsi Devices

    Step 1. Plug the 68-pin connector on the end of the SCSI ribbon cable into the internal connector on the host adapter, as Figure 2.8 shows. Figure 2.8 Connecting Internal SCSI Cable to Host Adapter Detailed Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 23: Connecting Multiple Internal Scsi Devices

    SCSI host adapter. Refer to Section 2.4, “Terminating the SCSI Bus,” on page 2-11 details on SCSI bus termination. Connecting SCSI Devices Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 24: Connecting The Led Cable

    J5. If the LED does not light up when there is SCSI activity, move the connector to the other half of J5. Detailed Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 25: Connecting External Scsi Devices

    SCSI device. If you have the correct cable, it matches the external connector. Figure 2.11 Connecting One External SCSI Device Terminator Connecting SCSI Devices Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 26: Connecting Multiple External Scsi Devices

    SCSI device, as Figure 2.12 shows. Refer to Section 2.4, “Terminating the SCSI Bus,” on page 2-11 for details on SCSI bus termination. 2-10 Detailed Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 27: Terminating The Scsi Bus

    SCSI bus. Termination for host adapters with only one connector per channel is always enabled for the channel. Terminating the SCSI Bus 2-11 Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 28: Setting Scsi Ids

    SCSI ID Record for Dual Channel Host Adapter SCSI ID SCSI Device Channel A SCSI Device Channel B Ultra320 SCSI host adapter Ultra320 SCSI host adapter 2-12 Detailed Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 29: Completing The Installation

    Integrated Mirroring™ (IM) solution, which provides features of RAID 1 and RAID 1E • Integrated Striping™ (IS) solution, which provides features of RAID 0 Completing the Installation 2-13 Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 30: Integrated Mirroring Solution

    To set up the Integrated RAID (IM and IS) features, refer to the Integrated RAID User’s Guide. 2-14 Detailed Host Adapter Installation Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 31: Ultra320 Scsi Host Adapter Characteristics

    6.6 x 3.27 inches, 167.6 x 83.1 mm LSI21320-R Dual Channel IR support Standard 6.6 x 3.27 inches, 167.6 x 83.1 mm Ultra320 SCSI Host Adapters User’s Guide Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 32: Lsi20320 Single Channel Host Adapters

    PCI standard and PCI low profile bracket types. 3.1.1 LSI20320 Single Channel Host Adapters The LSI20320 series of host adapters are single channel Ultra320 SCSI host adapters that provide one Ultra320 SCSI channel. The SCSI Channel A interface is made through connectors J1 and J3.
  • Page 33: Lsi20320, Lsi20320-R, And Lsi20320L-R Host Adapter Drawing

    HDR2 Connector for Channel A LSI53C1020 Channel A Internal SCSI Connector Channel A Ultra320 SCSI LVD/SE J5 – PCI and PCI-X 64-Bit Edge Connector Ultra320 SCSI Host Adapters Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 34: Lsiu320 And Lsi20320A Single Channel Host Adapters

    During system initialization, the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller. Ultra320 SCSI Host Adapter Characteristics Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 35: Lsiu320, Lsiu320-R, Lsi20320A, And Lsi20320A-R Host Adapter Drawing

    LSIU320, LSIU320-R, LSI20320A, and LSI20320A-R Host Adapter Drawing J4 LED Connector Channel A Ultra320 SCSI LVD/SE LSI53C1020A Channel A Ultra320 SCSI LVD/SE J1 – PCI and PCI-X Ultra320 SCSI Host Adapters Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 36: Lsi20320Ie And Lsi20320Ile Single Channel Host Adapters

    During system initialization, the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller. Ultra320 SCSI Host Adapter Characteristics Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 37: Lsi20320Ie And Lsi21320Ile Host Adapter Drawing

    HDR2 Connector for Channel A LSI53C1020A Channel A Internal SCSI Connector PCIe Bridge Channel A Ultra320 SCSI LVD/SE J1 – PCI Express x4 Edge Connector Ultra320 SCSI Host Adapters Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 38: Lsi21320 Dual Channel Host Adapters

    During system initialization, the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller. Ultra320 SCSI Host Adapter Characteristics Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 39: Lsi21320 And Lsi21320-R Host Adapter Drawing

    A and B Channel A Channel B Ultra320 SCSI LVD/SE Ultra320 SCSI LVD/SE LSI53C1030 Channel A Ultra320 SCSI LVD/SE J1 – PCI and PCI-X Ultra320 SCSI Host Adapters Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 40: Lsi22320 Dual Channel Host Adapters

    During system initialization, the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller. 3-10 Ultra320 SCSI Host Adapter Characteristics Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 41: Lsi22320 And Lsi22320-R Host Adapter Drawing

    Ultra320 SCSI LVD/SE Ultra320 SCSI LVD/SE Channel B Ultra320 SCSI LVD/SE LSI53C1030T Channel A Ultra320 SCSI LVD/SE J1 – PCI and PCI-X Ultra320 SCSI Host Adapters 3-11 Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 42: Lsi22320Se And Lsi22320Sle Dual Channel Host Adapters

    During system initialization, the system loads the ID numbers into the Subsystem Vendor ID and Subsystem ID registers of the embedded SCSI controller. 3-12 Ultra320 SCSI Host Adapter Characteristics Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 43: Lsi22320Se And Lsi22320Sle Host Adapter Drawing

    Channel A LSI53C1030 PCIe Bridge J2 and J3 Channel A and B Ultra320 SCSI LVD/SE J1 – PCI Express x4 Edge Connector Ultra320 SCSI Host Adapters 3-13 Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 44: Host Adapter Characteristics

    3.3.1 Electrical Characteristics Table 3.3 lists the maximum power requirements for standard Ultra320 SCSI host adapters, including SCSI TERMPWR, under normal operation. 3-14 Ultra320 SCSI Host Adapter Characteristics Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 45: Thermal And Atmospheric Characteristics

    The following parameters define the storage and transit environment for the Ultra320 SCSI host adapters: • Temperature range: −40 °C to 105 °C (dry bulb) • Relative humidity range: 5% to 90% noncondensing Technical Specifications 3-15 Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 46: Safety Characteristics

    UL flammability rating. Because these boards are installed in a PCI bus slot, all voltages are below the SELV 42.4 V limit. 3-16 Ultra320 SCSI Host Adapter Characteristics Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 47: Appendix A Glossary Of Terms

    SCSI hardware, and the operating system level drivers that support these architectures. Fusion-MPT architecture offers a single binary, operating system driver that supports both Fibre Channel and SCSI devices. Ultra320 SCSI Host Adapters User’s Guide Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 48 A piece of hardware (such as a disk drive, printer, or CD-ROM) used with Device a computer and under the computer’s control. SCSI peripheral devices are controlled through a SCSI host adapter. Glossary of Terms Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 49 A standard for SCSI data transfers. It allows a transfer rate of up to 20 Mbytes/s over an 8-bit SCSI bus and up to 40 Mbytes/s over a 16-bit SCSI bus. Glossary of Terms Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 50 A standard for SCSI data transfers. It allows a transfer rate of up to 320 Mbytes/s over a 16-bit SCSI bus. VHDCI Very High Density Cable Interconnect. VHDCI cables connect external SCSI devices to the host adapter. Glossary of Terms Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 51: Customer Feedback

    Thank you for your help in improving the quality of our documents. Ultra320 SCSI Host Adapters User’s Guide Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.
  • Page 52 Please complete the information below so that we may contact you directly for clarification or additional information. Name Date Telephone Title Department Mail Stop Company Name Street City, State, Zip Customer Feedback Version 2.3 Copyright © 2002–2004, 2006 by LSI Logic Corporation. All rights reserved.

Table of Contents