Counter Interrupt Flag
The interrupt flag bit is a flag indicating the status of an interrupt. It is a
readable/writable bit. To find the status of the interrupt, you have to read
the bit value; to clear the interrupt, you have to write "1" to this bit. This
bit must first be cleared to service the next coming interrupt. Besides, you
can choose if counter 0 or counter 1 generate interrupt signal by configur-
ing "CTR0IntSet" and "CTR1IntSet" control bit.
Table 2.14: Counter Interrupt Flag Control Bit
Read
Write
CTR0IntSet, CTR1IntSet
Cascaded 32-bit Counter
You can also cascade counter 0 and counter 1 together as one 32-bit
counter/timer, and it's configured by the control bit - CTR32Set.
Table 2.15: 32-bit Counter Control Bit
0
1
2.7 LAN: Ethernet Connector
The UNO-2050G is equipped with two Realtek RTL8139DL Ethernet
LAN controller that is fully compliant with IEEE 802.3u 10/100Base-T
CSMA/CD standards. The Ethernet port provides a standard RJ-45 jack
on board, and LED indicators on the front side to show its Link (Yellow
LED) and Active (Green LED) status. Please refer to A.4 for its pin
assignments.
UNO-2050G User Manual
CTR0F, CTR1F
0
1
0
1
0
1
Cascade counter 0 and counter 1 into one 32-bit counter
Counter Interrupt Status
No interrupt
Interrupt occur
Don't care
Clear interrupt
Counter Interrupt Control
Disable (Default)
Enable
Disable (Default)
20