Register 5: Watchdog Timer Time-Out Trigger Status (Wdttr); Register 6: Watchdog Timer Interrupt Control Register (Wdtintctr) - Advantech UNO-4673A Series User Manual

Intel atom d510/core i7 substation computers with 6 x lan, 2 x com and 3 x expansion slots
Table of Contents

Advertisement

B.1.5

Register 5: WatchDog Timer Time-Out Trigger Status (WDTTR)

OFFSET = 0x010
WDTTR saves the occurrence times of watchdog timer time-out. The corresponding
operation differs from the access type which is taken on WDTTR. A read-out from
WDTTR would clear the watchdog interrupt while a write-in clear WDTTR.
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
User
Settings
Reserved
Bits
Access
31:8
RO
7:0
R/W
B.1.6
Register 6: WatchDog Timer Interrupt Control Register
(WDTINTCTR)
OFFSET = 0x014
Based on the watchdog timer time-out frequency which is stored in WDTTR,
WDTINTCTR sets the period of interrupt. WDTTR plus one as watchdog timer time
out occurred. While the number of occurrences exceeds the value saved in
WDTINTCTR, an interrupt would be issued.
Bit
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
User
Settings
Reserved
Bits
Access
31:8
RO
7:0
R/W
UNO-4673A/4683 Series User Manual
Name D
Description
-
Reserved 0
x00 = reset
WDTTR
Watchdog Timer time-out counter:
The correlative operation is upon the access
type.
0xFF = reset
Read-out = clear the watchdog interrupt
Write-in = clear WDTTR
Name D
Description
-
Reserved 0
x00 = reset
WDTINTCTR
Interrupt Occurrence Frequency Setup:
An interrupt issued when the number of times of
watchdog timer
time-out is greater than the value store in
WDTINTCTR.
0x00 = reset
40