Following table shows the default settings at the factory.
Display Message
Meaning
Al EMULATION
STD
Standard emulation mode is selected.
A2 RAM
BUFFER
RAM is used as the print buffer.
A3 QUIET
OFF
Quiet mode is cancelled.
A4 GRAPH
DIR BI
Bi-directional
printing is selected for graphics.
A5 AUTO-ONLINE
Y
1 Auto on-line mode is selected.
Bl MODE
LQ/SLQ
LQ/SLQ mode is selected.
B2 LD
ROMAN
Roman font is selected for LQ/SLQ mode.
Cl STD
GRAPH
Graphic set is selected for Standard character set.
C2 IBM
I
BM12
Set #2 is selected for IBM character set.
C3 ZERO
NORMAL
Normal zero character is selected.
C4 CODEPAGE
#437
Code Page #437 (U.S.A.) is selected.
C5 COUNTRY
USA
U.S.A. character set is selected.
Dl ITALIC
0 F F
1 Italic print mode is cancelled.
I
D2 PITCH
10
Pica pitch (10 CPI) is selected.
El MULTIPART
OFF
Multi-part mode is cancelled.
E2 PAPER-OUT
ON
Paper-out detector is enabled.
E3 ASF
0 F F
Optional ASF is not installed.
E4 T.MGN-CUT
l/6
Top margin for cut forms is set to l/6 inch.
E5 T.MGN-ASF
l/6
Top margin for ASF is set to l/6 inch.
E6 T.MGN-TRA
l/6
Top margin for fanfold forms is set to l/6 inch.
E7 BOTTM MGN l/6
Bottom margin is set to l/6 inch.
E8 L.P.I.
6
6
lines can be printed on one inch.
Fl AUTO-LF
OFF
LF must be from host.
F2 AUTO-CR
ON
Auto CR with LF.
F3 TEAR-OFF
OFF
Tear-off function is disabled.
F4 SK I P - PER F 0 F F
1 Skip-over-perforation
is disabled.
I
F5 PAGE-LGTH
11
Page length is set to 11 inches.
Gl STROBE
NORMAL
Set the normal interface timing.
G2
EDS
CURRENT
Set the current EDS settings.