Display real-time status information about all installed transceivers,
including non-operational transceivers.
Figure 10-8 shows sample output from the show tech transceivers command.
ProCurve# show tech transceivers
Transceiver Technical Information:
Port # |
Type
-------+-----------+--------+------------------+----------
9
| 1000SX
10
| 1000LX
Figure 10-8. Example of Show Tech Transceivers Command
Operating Notes:
■
The following information is displayed for each installed transceiver:
•
Port number on which transceiver is installed.
•
Type of transceiver.
•
Product number—Includes revision letter, such as A, B, or C. If no
revision letter follows a product number, this means that no revision
is available for the transceiver.
•
Part number—Allows you to determine the manufacturer for a spec
ified transceiver and revision number.
■
For a non-ProCurve installed transceiver (see line 23 Figure 10-8), no
transceiver type, product number, or part information is displayed. In the
Serial Number field, non-operational is displayed instead of a serial num
ber.
■
The following error messages may be displayed for a non-operational
transceiver:
• Unsupported Transceiver. (SelfTest Err#060)
Check: www.hp.com/rnd/device_help/2_inform for
more info.
• This switch only supports revision B and above
transceivers. Check: www.hp.com/rnd/device_help/
2_inform for more info.
• Self test failure.
• Transceiver type not supported in this port.
Viewing Port Status and Configuring Port Parameters
| Prod # | Serial #
| J4858B | CN605MP23K
| J4859C | H117E7X
Port Status and Configuration
| Part #
|
| 2157-2345
10-15
Need help?
Do you have a question about the PROCURVE 2520 and is the answer not in the manual?