Testing In Shore Power Mode - Xantrex XM 1000 Owner's Manual

Xpower pro inverter
Hide thumbs Also See for XM 1000:
Table of Contents

Advertisement

Xantrex_PRO1800.book Page 25 Tuesday, April 24, 2007 11:33 AM
4. Turn the appliance on to verify that it operates.
If the appliance operates, your installation is successful. If your installation
has AC input and output hardwired to the XM 1800, proceed to "Testing in
Shore Power Mode".
If the status LED on the display panel glows red, see the Troubleshooting
chapter.

Testing in Shore Power Mode

To test the XM 1800 in shore power mode:
◆ With the appliance from the previous test still connected and operating,
Note:
supply the appliances with inverter power if the shore power source fails or
becomes disconnected.
If the on/off button on the XM 1800 is on and shore power voltage is too low (less
than 90 volts AC), the unit will transfer to inverter power to continue running your
appliances.
Note:
XM 1800.
975-0263-01-01
connect the shore power source.
The XM 1800 transfers the appliances to shore power. The status LED
on the display panel glows green.
If the appliance operates, your installation is successful.
If the on/off button on the XM 1800 is on, the XM 1800 will automatically
Whether or not the on/off button is on, shore power will pass through the
Testing Your Installation
3–25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm 1800Xpower xm 1800

Table of Contents