Xantrex_PRO1800.book Page 20 Tuesday, April 24, 2007 11:33 AM
Installation
CAUTION!
Do not connect the AC OUT to any other
source of power. Damage to unit may occur.
INVERTER SUBPANEL
AC OUTLETS
INVERTER LOADS
Figure 3-6 AC Wiring Diagram with an Inverter Subpanel
In this wiring diagram, the AC input comes from the main AC panel which
acts as the circuit breaker from an AC source. The output is routed to a
separate circuit breaker acting as the inverter AC subpanel.
3–20
Note: Do NOT connect the
AC OUT Neutral and Line to the
TO DC LOADS
AC IN Neutral and Line.
MAIN AC PANEL
GENERATOR
TRANSFER SWITCH
975-0263-01-01
SHORE POWER