Calculating Fuse/Circuit Breaker Size - Xantrex XM 1000 Owner's Manual

Xpower pro inverter
Hide thumbs Also See for XM 1000:
Table of Contents

Advertisement

Xantrex_PRO1800.book Page 8 Tuesday, April 24, 2007 11:33 AM
Installation

Calculating Fuse/Circuit Breaker Size

Because your batteries can provide thousands of amps of short-circuit
current, you need fuses or circuit breakers that can safely interrupt the
short-circuit current that the batteries can produce.
To select the correct fuse type and size:
1. Determine the total short-circuit current rating for your batteries. For
Important:
rating is the sum of the short-circuit current ratings of all of the batteries
connected in parallel. For batteries connected in series, the total short-circuit
current rating is equal to the short-circuit rating of a single battery.
2. Once you have determined the total short-circuit current rating of
3. Pick the fuse/circuit breaker's current rating based on the product
Fuses can be bought at any marine supply store, RV supply store, or
electrical products store.
3–8
example:
If you are using one battery to power your inverter and its short-
circuit current rating is 500 A, the total short-circuit current rating
is 500 A.
If you are powering your inverter with two 12 V batteries
connected in parallel, and each battery has a short-circuit current
rating of 500 A, the total short-circuit current rating is 1000 A.
If you are powering your inverter with two 6 V batteries
connected in series, and each battery has a short-circuit current
rating of 500 A, the total short-circuit current rating is 500 A.
For batteries connected in parallel, the total short-circuit current
your batteries, pick the fuse/circuit breaker's interrupt capacity based
on the short-circuit current calculated in step 1.
used: 150 ADC (XM 1000) or 250 ADC (XM 1800).
975-0263-01-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm 1800Xpower xm 1800

Table of Contents