Xantrex XM 1000 Owner's Manual page 40

Xpower pro inverter
Hide thumbs Also See for XM 1000:
Table of Contents

Advertisement

Xantrex_PRO1800.book Page 21 Tuesday, April 24, 2007 11:33 AM
CAUTION!
source of power. Damage to unit may occur.
MAIN AC PANEL
AC OUTLETS
INVERTER LOADS
Figure 3-7 AC Wiring Diagram without an Inverter Subpanel
In this wiring diagram, the AC input comes directly from an AC source. The
AC input must be limited with (input) breaker protection of 15 amps for the
XM1000 and 20 amps for the XM1800. The output is routed to the main AC
panel or circuit breaker.
975-0263-01-01
TO DC LOADS
Do not connect the AC OUT to any other
Note: Do NOT connect the
AC OUT Neutral and Line to the
AC IN Neutral and Line.
TRANSFER SWITCH
Input breakers must
be provided by
installers.
AC Wiring
GENERATOR
SHORE POWER
3–21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm 1800Xpower xm 1800

Table of Contents