Xantrex_PRO1800.book Page 12 Tuesday, April 24, 2007 11:33 AM
Installation
Connecting the Chassis Ground
WARNING: Shock hazard
Never operate the XM 1800 without properly connecting the chassis ground. An
electrical shock hazard could result from improper grounding.
The XM 1800 has a ground stud on the side of the unit as shown in Figure
3-3. Follow the guidelines in "Grounding Locations" to connect the
inverter's chassis to the ground.
Figure 3-3 DC Panel Connections
Grounding Locations
You must connect the chassis ground stud to a grounding point—usually
the vehicle's chassis—using recommended copper wire (if insulated then
green insulation with or without one or more yellow stripes) or larger.
For recommended chassis ground cable size, see "Sizing the Chassis
Ground Cable" on page 3–7.
3–12
Chassis
ground stud
975-0263-01-01