Synchronous Port Table Objects
The Synchronous Port Table Objects contains an entry for the synchronous user
data port and the Management port when this port is configured for synchronous
operation. For this unit, entries in the table that are counters (rs232SyncPortEntry
3–7) are used to collect statistics only and are not supported. Clarification for
objects contained in this table as it applies to the unit is provided below.
7610-A2-GB20-10
Table C-9. Asynchronous Port Table Objects (2 of 2)
Object
Description
rs232AsyncPort
Specifies the type of parity
Parity
used by the port.
(rs232Async
PortEntry 4 )
rs232AsyncPort
Specifies the ability to
AutoBaud
automatically sense the
(rs232Async
input speed of the port.
PortEntry 5 )
Table C-10. Synchronous Port Table Objects (1 of 2)
Object
Description
rs232SyncPort
Specifies the clock source
ClockSource
for the port.
(rs232Sync
PortEntry 2 )
rs232SyncPort
Specifies whether this
Role
device interface is a DTE or
(rs232Sync
DCE.
PortEntry 8 )
rs232SyncPort
Specifies the bit encoding
Encoding
technique that this port
(rs232Sync
uses.
PortEntry 9 )
rs232SyncPort
Specifies the method used
RTSControl
to control the RTS signal.
(rs232Sync
Refer to Data Port Options,
PortEntry 10 )
Table A-3.
November 1997
MIB Descriptions
Setting/Contents
Supports only the following values:
none(1) – No parity bit
odd(2) – Odd parity
even(3) – Even parity
Supports only the following values:
disabled(2) – Does not support
Autobaud.
Setting/Contents
Supports only the following values:
internal(1) – The port uses an internal
clock.
split(3) – The port uses an external
transmit clock and internal receive clock.
Supports only the following value:
dce(2) – The port acts as a DCE.
Supports only the following value:
nrz(1) – The port uses non-return to
zero encoding.
Supports only the following values:
controlled(1) – For User Data port, this
value is used when the Data Port option
Carrier Control by RTS is set to
Switched.
constant(2) – For User Data port, this
value is used when the Data Port option
Carrier Control by RTS is set to
Constant. This is the only valid value for
the Management port.
C-15