Standard 2 Of - Datalogic Skorpio X3 User Manual

Skorpio x3
Hide thumbs Also See for Skorpio X3:
Table of Contents

Advertisement

Standard 2 of 5

Code
Parameter
Enables/disables the
Enable
Standard 2 of 5 symbology.
Enables more aggressive
Enable
decoding algorithms to be
Aggressive
used in order to scan hard
Decoding
to read labels.
Requires the use of
Enable
checksum characters to
Checksum
verify a bar code.
Instructs the terminal to
Send
include the checksum in
Checksum
the label transmission.
Allows the terminal to
recognize labels that are
Use 2-bar
printed using only two bars
Start/Stop
for start/stop characters.
Set the minimum label
Minimum
length to be less than or
Label
equal to maximum label
Length
length.
This feature specifies the
maximum allowable length
of a Standard 2 of 5 label.
Maximum
The length includes check
and data characters.
Label
Maximum Label Length
Length
should be greater than or
equal to Minimum Label
Length.
Sets the number of times a
Read
label must be read before it
Verification
is transmitted.
Specifies the symbology
identifier (if any) that is sent
when parameter Send
Code ID (Index 0025) is set
User ID
to 3. ASCII code zero (null)
is used to indicate that an
identifier is not to be sent
for the symbology.
140
Description
Accept.
I.D.#
Input
Enter 1 for On and 0 for Off
0200
On or Off
0201
On or Off
0202
On or Off
0203
On or Off
0204
On or Off
0220
01 - 50
0221
01 - 50
0222
01 - 04
Any
single
0223
ASCII
character
(00 = Off)
Defaults
Off
On
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
01
01
06
01
50
10
01
02
01
'F'
'F'
'F'
6
Scanner
Type