Code 93
Code
Parameter
Enables/disables the Code
Enable
93 symbology.
Enables more aggressive
Enable
decoding algorithms to be
Aggressive
used in order to scan hard
Decoding
to read labels.
Set the minimum label
Minimum
length to be less than or
Label
equal to maximum label
Length
length.
This feature specifies the
maximum allowable length
of a Code 93 label.
Maximum
The length includes check
and data characters.
Label
Maximum Label Length
Length
should be greater than or
equal to Minimum Label
Length.
Sets the number of times a
Read
label must be read before it
Verification
is transmitted.
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is
User ID
set to 3. ASCII code zero
(null) is used to indicate
that an identifier is not to
be sent for the symbology.
Description
Accept.
I.D.#
Input
Enter 1 for On and 0 for Off
0400
On or Off
0401
On or Off
0420
01 - 50
0421
01 - 50
0422
01 - 04
Any
single
0423
ASCII
character
(00 = Off)
Defaults
Off
On
Off
Off
On
Off
01
01
02
01
50
20
01
02
01
'L'
'L'
'L'
Scanner
Type
131