Datalogic Skorpio X3 User Manual page 153

Skorpio x3
Hide thumbs Also See for Skorpio X3:
Table of Contents

Advertisement

GS1 DataBar Expanded
Code
Parameter
Enables/disables the GS1
DataBar Expanded
Enable
symbology.
Instructs the decoder to
transmit the label data as
Convert to
one or more GS1-128
GS1-128
labels.
Sets the minimum bar code
label length to be less than
Minimum
or equal to maximum label
length.
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is set
User Code ID
to 3. ASCII code zero (null)
is used to indicate that an
identifier is not to be sent
for the symbology.
Description
0810
0814
0824
0825
0827
I.D.#
Accept. Input
Enter 1 for On and 0 for Off
On or Off
On or Off
1 - 74
1 - 74
Any
single
ASCII
character
(00 = Off)
Scanne
Defaults
r Type
Off
On
On
Off
On
Off
01
01
01
01
74
74
'R'
'R'
'R'
145