Code 128

Code
Parameter
Enables/disables the Code 128
Enable
symbology.
Enable
Enables more aggressive decoding
algorithms to be used in order to
Aggressive
scan hard to read labels.
Decoding
Enable GS1-128 variant of Code
GS1-128
128 (independent of Code 128).
Enable
Enable Extended ASCII character
conversion. This enables the ability
Code 128
of Code 128 labels to use the FNC4
Extended
character to encode Extended ASCII
ASCII Enable
characters, as defined by the latest
Code 128 symbology specification.
Minimum
Set the minimum label length to be
less than or equal to maximum label
Label
length.
Length
This feature specifies the maximum
allowable length of a Code 128
Maximum
label. The length includes check and
Label
data characters. Maximum Label
Length
Length should be greater than or
equal to Minimum Label Length.
Sets the number of times a label
Read
must be read before it is transmitted.
Verification
Specifies the symbology identifier (if
any) that is sent when parameter
Send Code ID (Index 0025) is set to
User ID
3. ASCII code zero (null) is used to
indicate that an identifier is not to be
sent for the symbology.
132
Description
Accept.
I.D.#
Input
Enter 1 for On and 0 for Off
0408
On or Off
Off
0409
On or Off
Off
040C
On or Off
Off
040F
On or Off
Off
0424
01 - 80
0425
01 - 80
0426
01 - 04
Any
single
0427
ASCII
character
(00 = Off)
Scanner
Defaults
Type
On
On
On
Off
On
Off
On
On
01
01
02
01
80
40
01
02
01
'K'
'K'
'K'
6