Id Address Selection; Temperature Control Functions - Blizzard Lighting ToughPAR Fab5 User Manual

Professional led par fixture
Hide thumbs Also See for ToughPAR Fab5:
Table of Contents

Advertisement

AR2.S
6.)
- Architectural Mode #2 w/strobe (RGBAW, 7-Ch.)
Channel
1
2
3
4
5
6
7
HSV
7.)
- Hue, Saturation, Value (3-Ch.)
Channel
1
2
3
ID

ID Address Selection

ID Address mode allows you to utilize up to 2,574 fixtures on only 1 DMX
universe while maintaining full individual control over each fixture. You can
enable or disable ID address operation within the
are found in
• Id.01 - Id.66
TEMP
Temperature Functions
Allows the user to set a temperature protection cutoff (default is 85 degrees
Celsius), and displays the current fixture temperature.
• CURR
• • TOP
The ToughPAR Fab5 (s) Manual Rev. A
Value
What It Does
000 <--> 255 Master Dimmer (0% <--> 100%)
000 <--> 255 Red Intensity (0% <--> 100%)
000 <--> 255 Green Intensity (0% <--> 100%)
000 <--> 255 Blue Intensity (0% <--> 100%)
000 <--> 255 Amber Intensity (0% <--> 100%)
000 <--> 255 White Intensity (0% <--> 100%)
000 <--> 255 Strobe
Value
What It Does
000 <--> 255 Hue (0% <--> 100%)
000 <--> 255 Saturation (0% <--> 100%)
000 <--> 255 Brightness (0% <--> 100%)
STAG
mode, channel 11.
- Sets the ID# for the fixture.
- Displays current temperature.
- Sets the max temperature before shutoff (0-150, 85=default).
SET
(see stage mode table on page 12)
Page 14
menu. Control settings
.
© 2012-13 Blizzard Lighting, LLC

Hide quick links:

Advertisement

Table of Contents
loading