NEC Express5800/R120b-1 User Manual page 112

Express5800/r120b-1
Table of Contents

Advertisement

Option
Boot Monitoring
Policy
Thermal Sensor
Check previous
System Config
BMC IRQ
Post Error Pause
Memory Error
Power Switch
Inhibit
AC-LINK
Power ON Delay
Time
Platform Event
Filtering
CLI SETUP
Parameters
Specify the processing when a timeout occurs during
[Retry 3 Times]
boot monitoring. This option can only be specified if
Always Reset
[Boot Monitoring] is specified.
If [Retry 3 times] is selected, the system is reset after
the occurrence of a timeout and booting up the OS is
retried up to three times.
If [Always Reset] is selected, the system is reset
after the occurrence of a timeout and booting up the
OS is retried repeatedly.
Specify whether to enable or disable the thermal
Disabled
sensor monitoring function. If a thermal error is
[Enabled]
detected with this item set to [Enabled], the system
stops at the end of POST.
Disabled
If the system configuration has been changed since
the previous startup, the system waits for user
[Enabled]
intervention before booting the system.
[IRQ 11]
Determines routing of the BMC interrupt.
Disabled
Disabled
Specify whether to stop the POST once at the end of
POST if an error occurs during the POST.
[Enabled]
Halt
Specify whether to stop operation once at the end of
POST processing if there is a memory resource error
[Boot]
while executing POST processing. This setting is
effective if [POST Error Pause], which is on the
[Server] menu, is set to [Enabled].
Even if this option is set to [Boot], operation stops at
the end of POST processing if errors occurred for all
resources.
[Disabled]
Specify whether to enable or disable the power
switch.
Enabled
Note that it is not possible to disable the ability to
forcibly turn off the power by holding down the switch
for four seconds.
Stay Off
Specify the state of power when the AC power to the
server is turn off once and then on.
[Last State]
Power On
[20] - 255
Specify the power on delay time within the range
between 20 and 255 seconds. The time specified is
valid when "Power On" or "Last State" is specified for
AC LINK.
Disabled
Specify whether to enable or disable the platform
event filtering (PEF) feature.
[Enabled]
Set to [Enabled] to run the CLI SETUP (Command
[Disabled]
Line Interface SETUP Menu) instead of SETUP
Enabled
menu of this GUI. To use the SETUP menu of this
GUI, set this item to [Disabled] on CLI SETUP menu.
Configuring Your Server 4-25
Description
[
]: Factory-set

Advertisement

Table of Contents
loading