4) Remove the connector, the paper cassette paper feed clutch
unit, the paper transport clutch unit, and the resist roller clutch
unit.
5) Remove the parts.
b-1. Drum motor
b-2. Main motor
1) Remove the screw, and remove the rear cabinet.
2) Remove the connector and the screw, and remove the drum
motor and the main motor.
AR-M351U/M451U, AR-M355U/M455U MAINTENANCE AND DETAILS OF EACH SECTION 7 - 69

11. Power section

A. Maintenance and parts replacement
No.
Unit
a
Power unit
1
2
3
b
1
2
3
4
b-4
b-3
a-2
a. Power unit
1) Remove the main switch mounting plate.
2) Remove the screw, and remove the right cabinet.
3) Remove the screw, and remove the right noise cover.
Parts
Reactor PWB (200V only)
Filter PWB (Taiwan only)
Power PWB
Relay PWB
Main switch
Cooling fan motor
Fuse PWB
High voltage PWB
b-2
a-1
b-1