Sharp AR-M355U Service Manual page 149

Digital multifunctional system
Hide thumbs Also See for AR-M355U:
Table of Contents

Advertisement

18*1
MCLUM
MP tray lift-up motor signal
19*2
MPFS
Manual paper feed solenoid signal
20*2
MPFC
Manual paper feed clutch signal
21*2
MSS
Manual paper feed gate solenoid
*1: Displayed when OPTION of multi-purpose only.
*2: Displayed when manual feed OPTION is added.
SIMULATION 6-1
FEED OUTPUT CHECK. SELECT 1-22, AND PRESS START.
1.MSWPR
2.HLPR 3.DCPR 4.MM
7.DSB_RV 8.CPFC 9.RRC
12.LUM
13.TRC_DSK
15.MCM
16.MCPCL
19.MPFS
20. MPFC
Press [START] key, and the
operation is started.
SIMULATION 6-1
FEED OUTPUT CHECK. EXECUTING ... .
1.MSWPR
2.HLPR 3.DCPR 4.MM
7.DSB_RV 8.CPFC 9.RRC
12.LUM
13.TRC_DSK
15.MCM
16.MCPCL
19.MPFS
20.MPFC
6-2
Purpose
Operation test/Check
Function
Used to check the operations of each fan motor
(Purpose)
and its control circuit.
Section
Other
Item
Operation
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [CUSTOM SETTINGS] key to stop the operation.
1
Fan motor high speed
2
Fan motor low speed
3
Cooling fan motor (Controller/HDD)
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-3, AND PRESS START.
1.FMHi
2.FMLo
3.CFM-ICU/HDD
Press [START] key, and the operation
is started.
SIMULATION 6-2
FAN MOTOR CHECK..
2.FMLo
5.DM
6.DSB_FW
10.TRC 11.FGS_FIN
2
14.PSPS
17.MCFCL 18.MCLUM
21.MSS
22.MSWS
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after
repeating the operation several times.
5.DM
6.DSB_FW
10.TRC 11.FGS_FIN
2
14.PSPS
17.MCFCL 18.MCLUM
21.MSS
22.MSWS
2
Press [CUSTOM SETTINGS] key, and
the operation is stopped.
2
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 13
7
7-1
Purpose
Setting
Function
Used to set the operating conditions of aging.
(Purpose)
Section
Item
Operation
Operation/Procedure
1) Select the number corresponding to the operating condition of
aging with 10-key.
The combined mode of 0 - 6 mode and 10, 20, or 30 mode can
be set.
In that case, the number corresponding to one of 0 - 6 mode
and the number corresponding to one of 10, 10, and 30 mode
are added and the sum number is entered.
2) Press [START] key.
The condition selected in procedure 1) is set.
The setting of this simulation is kept valid until the power is turned
off.
0
NO MISS FEED DETECTION No jam detection
1
AGING
2
AGING/NO MISS FEED
DETECTION.
3
AGING/NO MISS FEED
DETECTION/NO WARM UP/
NO TEMPERATURE
CONTROL.
4
NO WARM UP.
5
AGING/INTERVAL.
6
AGING/INTERVAL/NO MISS
FEED DETECTION.
+10 NO PROCESS UNIT CHECK. Above +10: No process unit
+20 NO SHADING.
+30 NO PROCESS UNIT CHECK/
NO SHADING.
SIMULATION 7-1
AGING TEST SETTING. SELECT 0-36, AND PRESS START.
0.NO MISS FEED DETECTION
1.AGING
2.AGING/NO MISS FEED DETECTION.
3.AGING/NO MISS FEED DETECTION/
NO WARM UP/NO TEMPERATURE CONTROL.
4.NO WARM UP.
5.AGING/INTERVAL.
6.AGING/INTERVAL/NO MISS FEED DETECTION.
+10:NO PROCESS UNIT CHECK.
+20:NO SHADING.
+30:NO PROCESS UNIT CHECK/NO SHADING.
Press [START] key to start registration and operation.
The operation mode is kept until the power is turned off or setting is made again.
Aging mode
No jam detection, aging
mode
No jam detection/ no warm-
up/ no fusing temperature
control, aging mode
No warm-up
Intermittent aging mode
No jam detection
intermittent aging mode
(including the developing
unit) detection
Above +20: No shading
Above +30: No process unit
detection /no shading
2