Sharp AR-M355U Service Manual page 197

Digital multifunctional system
Hide thumbs Also See for AR-M355U:
Table of Contents

Advertisement

(Scan off-center position adjustment)
1) Enter the scan image position adjustment value with 10-key.
2) Press [P] key or [START] key.
When [START] key is pressed, the adjustment value is set and
copying is performed.
Normal display
ERROR display
Door open
Jam
Paper empty
Check the off-center of the printed image.
Repeat the above procedures until a satisfactory result is
obtained.
(UNIT: 0.1mm/step When the adjustment value is increased, the
print image is shifted to the front direction.)
(Copy condition setting in this simulation)
To select paper (paper feed tray), perform the following proce-
dures.
1) Enter 0 with 10-key.
2) Press [START] key. (The mode is changed to the paper feed
tray selection mode.)
3) Enter the number corresponding to the paper feed tray to be
used with 10-key. (Select one of 1 - 6)
4) Press [START] key. (The paper feed tray is selected.)
1
TRAY1
2
TRAY2
3
TRAY3
4
TRAY4
5
BPT
When the total of the above set value (1 - 5) and 10 is entered, the
mode is changed to the duplex print mode.
To set the copy magnification ratio, perform the following proce-
dure.
1) Enter 2 with 10-key.
2) Press [START] key.
3) Enter the copy magnification ratio with 10-key.
4) Press [START] key.
Set range
25 - 400 (%)
NOTE: When [P] key is pressed after entering the adjustment
value in this simulation, the adjustment value is set. When
[START] key is pressed, the adjustment value is set and
copying is performed.
NOW COPYING.
DOOR OPEN.
JAM
PAPER EMPTY.
TRAY1
TRAY2
TRAY3
TRAY4
Manual feed
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 61
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 0-9, AND PRESS
START.
0.TRAY SELECT
1
1.COPY START
2.MAGNIFICATION
100
(ADJUSTMENT DATA)
3.PLATEN
50
4.SPF SIDE1
Select other than 0 - 2, and press [START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. INPUT VALUE 0-99, AND
PRESS START.
3.PLATEN
Select 1,
Press [START] key.
and press
[START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. NOW COPYING.
Select 0, and press [START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT. SELECT 1-15, AND PRESS
START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT
(ABOVE+10: DUPLEX MODE)
Select 2, and
press [START] key.
SIMULATION 50-12
ORIGINAL OFF-CENTER ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
50-27
Purpose
Adjustment
Function
Used to adjust the image loss of the scan image in
(Purpose)
the FAX/scan mode.
Item
Picture quality
Operation/Procedure
(Select the scan mode to be adjusted.)
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(Shift for the adjustment value change: 1.0mm/step)
Item
FAX send
1
OC (LEAD_EDGE)
OC lead edge
2
OC (FRONT/REAR)
OC side
3
OC (TRAIL_EDGE)
OC rear edge
4
SPF (LEAD_EDGE)
SPF lead edge
5
SPF (FRONT/REAR) SPF side
6
SPF (TRAIL_EDGE) SPF rear edge
7
CIS (LEAD_EDGE)
CIS lead edge
8
CIS (FRONT/REAR) CIS side
9
CIS (TRAIL_EDGE)
CIS rear edge
2
50
5.SPF SIDE2
50
Press [CUSTOM SETTINGS] key.
50
Press [CUSTOM SETTINGS] key,
or terminate copying.
Press [START] key or
press [CUSTOM SETTINGS] key.
1
Press [START] key, or
press [CUSTOM SETTINGS] key.
100
Set range
Default
0 - 10
3
(Unit 1mm)
(3mm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m455uAr-m351uAr-m451uAr-m351nAr-m451n