SIMULATION 41-3
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200
PD2[128]: 200
PD3[128]:
50
PD4[128]:
PD5[128]:
51
PD6[128]:
PD7[128]:
52
43
43-1
Purpose
Setting
Function
Used to set the fusing temperature in each
(Purpose)
operation mode.
Section
Fixing (Fusing)
Item
Operation
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Press [CUSTOM SETTINGS] key.
4) Press [START] key.
Item
1
INSIDE NORMAL
2
OUTSIDE NORMAL
3
INSIDE PREHEAT
4
OUTSIDE PREHEAT
SIMULATION 43-1
FUSER TEMPERATURE SET. SELECT 1-4, AND PRESS START.
1. INSIDE NORMAL
190
2. OUTSIDE NORMAL
190
3. INSIDE PREHEAT
150
4. OUTSIDE PREHEAT
150
Press [START] key.
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
44
44-1
Purpose
Setting
Function
Used to set enable/disable of correction
(Purpose)
operations in the image forming (process) section.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Operation
Operation/Procedure
When bit =1, correction is made.
Bit
15
14
13
12
11
10
9
0
0
0
0
0
0
0
52
50
Default
Heater inside/normal
190
Heater outside/normal
190
Heater inside/preheat
150
Heater outside/preheat
150
1
Press [CUSTOM SETTINGS] key.
190
8
7
6
5
4
3
2
1
Vg4
Vg3
Vb1
0
Vb4
Vbr
Vb3
Ld2
Vg2
Ld1
Vb2
Ld4
Ld3
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 34
SIMULATION 44-1
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-255
AND PRESS START.
BIT0:Vg1, BIT1:Ld1, BIT2:Vg2,
BIT4:Vb1, Vb2
BIT5:Vg3, Vb3, Ld3
BIT6:Vbr
BIT7:Vg4, Vb4, Ld4
44-4
Purpose
Setup
Function
Used to set the target image (reference) density
(Purpose)
level in the developing bias voltage correction.
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Data
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
1
TEMP. AREA *1
2
HUMIDITY AREA *1
3
S_WT
4
Vb1
5
Vb2
*1: Only when this value is 0, control is made with the actual mea-
surement value of the process thermistor (temperature/humid-
ity). When it is not 0, control is made with the forcible setting
value.
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. SELECT 1-5 AND PRESS
START.
1.TEMP. AREA
2.HUMIDITY AREA
3.S_WT
100
4.Vb1
50
5.Vb2
50
Press [START] key.
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. INPUT VALUE, AND PRESS
START.
3.S_WT
0
Vg1
BIT3:Ld2
111
Item
Process environment temperature
forcible setting value
(0 - 13 /normal: 0)
Process environment humidity
forcible setting value
(0 - 14 /normal: 0)
Vb rising correction standby time
(0 - 180 sec/default: 90)
Vb correction amount (first rotation)
(0 - 150V/default: 50)
Vb correction amount (second
rotation) (0-50V/default: 15)
0
0
Press [CUSTOM SETTINGS] key.
101
3