Sharp AR-M355U Service Manual page 221

Digital multifunctional system
Hide thumbs Also See for AR-M355U:
Table of Contents

Advertisement

66-43
Purpose
Setting
Function
PIC adjustment value writing (Only when FAX is
(Purpose)
installed)
Section
FAX
Item
Operation
Operation/Procedure
To execute this simulation, FAX program writing must be allowed.
(Jumpers and DIP SW depending on the model.) The adjustment
values in PIC are changed or rewritten.
1) Enter the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value.
4) Press [P] key.
5) Select 0.
6) The confirmation window is displayed. Select whether the PIC
adjustment values are written or not.
YES
The adjustment values are collectively written into PIC
installed in the FAX BOX.
NO
No writing
When writing of the PIC adjustment values is normally completed,
"OK" is displayed. In case of an error, "NG" is displayed.
Item
0 WRITING for PIC
Writing to PIC
1 ci_level_judge
Number of sensing
until the CI signal
level is setteld.
2 ci_cycle_min
CI signal cycle
min. Time
3 ci_cycle_max
CI signal cycle
max. time
4 ci_range
CI signal allowable
range
5 ci_count
CI signal
settlement number
of times
6 ci_detect
CID IN- signal
settlement number
of times
7 fnet_level_judge
Sense number of
times until
settlement of
FNET signal level
8 fnet_range
FNET signal
allowable range
9 fnet_time_out
FNET time out
time
10 fnet_count
FNET signal
settlement number
of times
11 poff_time
PON signal OFF
time
12 mswon_level_judge Sense number of
times until
settlement of
MSW_ON signal
level
Content
-
-
1-15
2
0-254
10
0-254
107
0-127
5
1-15
3
1-15
8
1-15
1
0-74
3
76-255
100
1-15
3
0-15
3
2-15
3
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 85
PIC ADJUSTMENT VALUE WRITING.
ENABLE WRITE PIN(for FAX PROGRAM ROM).
SELECT 0-12, AND PRESS START.
0.WRITING for PIC
1.ci_level_judge
2.ci_cycle_min
10
3.ci_cycle_max
5.ci_count
3
6.ci_detect
8.fnet_range
3
9.fnet_time_out
11.poff_time
3
12.mswon_level_judge
Select other then 0 , and
Press [CUSTOM SETTINGS] key
press [START] key.
or press [START] key.
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING. INPUT VALUE 1-15, AND
PRESS START.
1.ci_level_judge(1-15)
PIC ADJUSTMENT VALUE WRITING.
ARE YOU SURE ?
2.NO
Select 1.
PIC ADJUSTMENT VALUE WRITING.
EXECUTING...
SIMULATION 66-43
PIC ADJUSTMENT VALUE WRITING.
OK ( or NG )
2
107
4.ci_range
8
7.fnet_level_judge
100
10.fnet_count
3
or select 2.
Press [CUSTOM SETTINGS] key.
1
5
1
3
2
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m455uAr-m351uAr-m451uAr-m351nAr-m451n

Table of Contents