24
24-1
Purpose
Data clear
Function
Used to clear the misfeed counter, the misfeed
(Purpose)
history, the trouble counter, and the trouble
history. (The counters are cleared after completion
of maintenance.)
Item
Counter
Operation/Procedure
1) Select the counter to be cleared with 10-key.
2) Press [START] key.
The confirmation to clear is opened.
3) Select Yes/NO of counter clear with 10-key.
YES: Clear
NO: Not clear
4) Press [START] key.
1
PAPER JAM
Number of paper jams
2
SPF JAM
Number of SPF jams
3
TROUBLE
Number of troubles
SIMULATION 24-1
JAM/ TROUBLE COUNTER DATA CLEAR. SELECT1-3, AND
PRESS START.
1. PAPER JAM
2. SPF JAM
3. TROUBLE
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 24-1
* COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
* = PAPER JAM, SPF JAM, TROUBLE
24-2
Purpose
Data clear
Function
Used to clear the number of use (the number of
(Purpose)
prints) of each paper feed section.
Section
Paper feed
Item
Counter
Operation/Procedure
1) Select the counter to be cleared with 10-key.
2) Press [START] key.
The confirmation to clear is opened.
3) Select Yes/NO of counter clear with 10-key.
YES: Clear
NO: Not clear
4) Press [START] key.
1
TRAY1
Tray 1 use quantity
2
TRAY2
Tray 2 use quantity
3
TRAY3/LCC1
Tray 3/LCC left tray use quantity
4
TRAY4/LCC2
Tray 4/LCC right tray use quantity
5
BPT
Manual feed tray use quantity
6
ADU
Duplex feed quantity
1
1
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 24
SIMULATION 24-2
PAPER FEED COUNTER DATA CLEAR. SELECT1-6, AND PRESS
START.
1. TRAY1
2. TRAY2
3. TRAY3/LCC1
4. TRAY4/LCC2
5. BPT
6. ADU
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 24-2
* COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
* = TRAY1,
TRAY2, TRAY3/LCC1, TRAY4/LCC2, BPT,
ADU
24-3
Purpose
Data clear
Function
Used to clear the number of use of the finisher,
(Purpose)
SPF, and the scan (reading) unit.
Section
Item
Counter
Operation/Procedure
1) Select the counter to be cleared with 10-key.
2) Press [START] key.
The confirmation to clear is opened.
3) Select Yes/NO of counter clear with 10-key.
YES: Clear
NO: Not clear
4) Press [START] key.
1
SPF
SPF paper pass quantity
2
SCAN
Number of times of document scan
3
STAPLER
Number of times of stapling
4
PUNCH
Number of times of punching
5
STAMP
Number of times of SPF finish stamp
SIMULATION 24-3
ORG./STAPLE COUNTER DATA CLEAR. SELECT 1-5, AND PRESS
START.
1. SPF
2. SCAN
3. STAPLER
4. PUNCH
5. STAMP
Press [START] key.
SIMULATION 24-3
* COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
* = SPF, SCAN, STAPLER, PUNCH, STAMP
1
1
1
Press [CUSTOM SETTINGS] key or
[START] key.