53-8
Purpose
Adjustment
Function
Used to adjust the document scan start position.
(Purpose)
(Used to adjust the scanner scan position in the
SPF mode front scan.)
Operation/Procedure
(Automatic adjustment)
1) Select 1 or 2 with 10-key.
2) Press [START] key.
(Manual feed adjustment)
1) Enter the adjustment value with 10key.
2) Press [START] key.
When an adjustment error occurs, the trouble code (E7-17) is dis-
played simultaneously with "COMPLETED."
Item
1
AUTO
Automatic adjustment
2
MANUAL
Manual feed adjustment
(Direct entry of a number)
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. PRESS START.
1.AUTO
2.MANUAL.
25
Select 2, and
Select 1, and
press [START] key.
press [START] key.
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT EXECUTING ... .
1. AUTO
Normal completion
Trouble occurrence
<Normal completion>
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT COMPLETED.
1. AUTO
<Trouble occurrence>
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT COMPLETED.
1. AUTO
SIMULATION 53-8
SPF SCANNING POSITION ADJUSTMENT. INPUT VALUE 1-70, AND
PRESS START.
2. MANUAL
Set
Default
range
1 - 70
32
(1 count:
0.1mm)
Press
[CUSTOM SETTINGS] key.
1
1
TROUBLE !!
(E7-17)
1
Press [START] key, or
press [CUSTOM SETTINGS] key.
25
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 64
55
55-1
Purpose
Setting
Function
Used to set the specifications of the engine control
(Purpose)
operations. (PCU PWB)
Section
Item
Operation
Operation/Procedure
This simulation is used to change and check the engine soft SW.
Set this setting to the default.
There is no need to change this setting in the market.
SIMULATION 55-1
ENGINNE SOFT SW. SETTING. SELECT 1-16, AND PRESS START.
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 55-1
ENGINNE SOFT SW. SETTING. INPUT DATA No(1-8), AND PRESS
START.
SOFT SW-1:
55-2
Purpose
Setting
Function
Used to set the specifications of the scanner
(Purpose)
control operations. (Scanner control PWB)
Section
Item
Operation
Operation/Procedure
This simulation is used to change and check the scanner soft SW.
Set this setting to the default.
There is no need to change this setting in the market.
SIMULATION 55-2
SCANNER SOFT SW. SETTING. SELECT 1-16, AND PRESS START.
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 55-2
SCANNER SOFT SW. SETTING. INPUT DATA No(1-8), AND PRESS
START.
SOFT SW-1:
Specifications
1
1 2 3 4 5 6 7 8
0 0 0 0 1 0 0 1
Specifications
1
1 2 3 4 5 6 7 8
0 0 0 0 1 0 0 1