66-9
Purpose
Operation test/Check
Function
Used to check the output operation of various
(Purpose)
sound signals of FAX. (Used to check the
operation of the sound output IC.) An output is
sent at the send level set by the soft switch. (Only
when FAX is installed)
Section
FAX
Item
Operation
Operation/Procedure
1) Enter the number corresponding to the output mode with 10-
key.
2) Press [START] key.
The output is delivered at the send level set with the soft SW.
1 NONE
Mute
2 PAUSE
Pause sound 12 MESSAGE10
3 MESSAGE1 MESSAGE 1 13 MESSAGE11
4 MESSAGE2 MESSAGE 2 14 MESSAGE12
5 MESSAGE3 MESSAGE 3 15 MESSAGE13
6 MESSAGE4 MESSAGE 4 16 MESSAGE14
7 MESSAGE5 MESSAGE 5 17 MESSAGE15
8 MESSAGE6 MESSAGE 6 18 ALARM
9 MESSAGE7 MESSAGE 7 19 RINGER
10 MESSAGE8 MESSAGE 8 20 EXT.TEL.RINGER External TEL ring
When the number is entered during execution, the kind of signal
can be changed.
When [START] key is pressed, the voice message is sent. When
[CUSTOM SETTINGS] key is pressed, it is stopped.
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.)
START.
1.NONE
2.PAUSE
4.MESSAGE2
5.MESSAGE3
7.MESSAGE5
8.MESSAGE6
10.MESSAGE8
11.MESSAGE9
13.MESSAGE11
14.MESSAGE12
16.MESSAGE14
17.MESSAGE15
19.RINGER
20.EXT.TEL.RINGER
Select other 1, and press [START] key.
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.)
START.
EXECUTING···.
1.NONE
2.PAUSE
4.MESSAGE2
5.MESSAGE3
7.MESSAGE5
8.MESSAGE6
10.MESSAGE8
11.MESSAGE9
13.MESSAGE11
14.MESSAGE12
Same
16.MESSAGE14
17.MESSAGE15
display
19.RINGER
20.EXT.TEL.RINGER
Select 2, and press [START] key.
SIMULATION 66-9
MESSAGE OUTPUT CHECK.(SOFT SW.)
START.
EXECUTING···.
1.NONE
2.PAUSE
4.MESSAGE2
5.MESSAGE3
7.MESSAGE5
8.MESSAGE6
10.MESSAGE8
11.MESSAGE9
13.MESSAGE11
14.MESSAGE12
16.MESSAGE14
17.MESSAGE15
19.RINGER
20.EXT.TEL.RINGER
Press [CUSTOM SETTINGS] key.
11 MESSAGE 9
MESSAGE 9
MESSAGE 10
MESSAGE 11
MESSAGE 12
MESSAGE 13
MESSAGE 14
MESSAGE 15
Alarm
Call ring
SELECT 1-20, AND PRESS
3.MESSAGE1
6.MESSAGE4
9.MESSAGE7
12.MESSAGE10
15.MESSAGE13
18.ALARM
Press [CUSTOM SETTINGS] key.
SELECT 1-20, AND PRESS
3.MESSAGE1
6.MESSAGE4
9.MESSAGE7
12.MESSAGE10
15.MESSAGE13
18.ALARM
SELECT 1-20, AND PRESS
3.MESSAGE1
6.MESSAGE4
9.MESSAGE7
12.MESSAGE10
15.MESSAGE13
18.ALARM
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 77
66-10
Purpose
User data output/Check (Display/Print)
Function
Used to clear all data of the image memory
(Purpose)
(memory send/receive). The confidential data are
also cleared at the same time. (Only when FAX is
installed)
Section
FAX
Item
Data
Operation/Procedure
1) Select YES/NO of image memory clear with 10-key.
1
YES
2
NO
2) Press [START] key.
The SRAM image data management table and image data in the
Flash ROM area and HD (except for filing images) are cleared.
SIMULATION 66-10
IMAGE MEMORY CLEAR
ARE YOU SURE?
1. YES
2. NO
Press [START] key to clear.
SIMULATION 66-10
IMAGE MEMORY CLEAR EXECUTING···.
++++++
The processing status of image memory clear is displayed with
"+."
66-11
2
Purpose
Operation test/Check
Function
Used to check the output operation of FAX G3
(Purpose)
mode 300bps. (Used to check the operation of
MODEM.) Send level: Max. (Only when FAX is
installed)
Section
FAX
Item
Operation
Operation/Procedure
1) Select the number corresponding to the output mode with 10-
key.
1
2) Press [START] key.
The signal is sent in the max. send level.
1
NO SIGNAL
2
11111
3
11110
When the number is entered during execution, the kind of signal
can be changed.
When [CUSTOM SETTINGS] key is pressed during execution, the
operation is stopped.
2
Image memory clear is executed.
Clear is not executed.
No signal
4
00000
11111
5
010101
11110
6
00001
1
1
00000
010101
00001