Sharp AR-M355U Service Manual page 162

Digital multifunctional system
Hide thumbs Also See for AR-M355U:
Table of Contents

Advertisement

SIMULATION 24-7
DRUM COUNTER DATA CLEAR. SELECT1, AND PRESS
START.
1. DRUM
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 24-7
* COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
* = DRUM
24-9
Purpose
Data clear
Function
Used clear the printer mode print counter and the
(Purpose)
self print mode print counter.
Section
Printer
Item
Counter
Operation/Procedure
1) Select the counter to be cleared with 10-key.
2) Press [START] key.
The confirmation to clear is opened.
3) Select Yes/NO of counter clear with 10-key.
YES: Clear
NO: Not clear
4) Press [START] key.
After replacing the OPC drum, be sure to clear the OPC drum
counter.
1
PRINTER
Printer counter (Print mode)
2
OTHERS
Other effective paper counter (Self print mode)
SIMULATION 24-9
PRINTER/OTHERS COUNTER DATA CLEAR. SELECT1-2, AND
PRESS START.
1. PRINTER
2. OTHERS
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 24-9
* COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
* = PRINTER, OTHERS
1
1
1
1
AR-M351U/M451U, AR-M355U/M455U SIMULATION 9 - 26
24-10
Purpose
Data clear
Function
Used to clear the FAX counter. (Only when FAX is
(Purpose)
installed)
Section
FAX
Item
Counter
Operation/Procedure
1) Select the counter to be cleared with 10-key.
2) Press [START] key.
The confirmation to clear is opened.
3) Select Yes/NO of counter clear with 10-key.
YES: Clear
NO: Not clear
4) Press [START] key.
1
FAX SEND
Number of times of FAX send
2
FAX RECEIVE
Number of times of FAX receive
3
FAX OUTPUT
FAX print quantity
4
SEND IMAGES
Send quantity
5
SEND TIME
Send time
6
RECEIVE TIME
Receive time
SIMULATION 24-10
FAX COUNTER DATA CLEAR. SELECT1-6, AND PRESS START.
1. FAX SEND
2. FAX RECEIVED
3. FAX OUTPUT
4. SEND IMAGES
5. SEND TIME
6. RECEIVE TIME
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
SIMULATION 24-10
* COUNTER DATA CLEAR.
ARE YOU SURE?
1. YES
2. NO
* = FAX SEND, FAX RECEIVED, FAX OUTPUT, SEND IMAGES,
SEND TIME, RECEIVE TIME
24-11
Purpose
Data clear
Function
Used to reset the OPC drum rotation time, and the
(Purpose)
DV unit rotation time counter. The developer
counter in the DV unit installed is reset.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Counter
Operation/Procedure
1) Select the counter to be cleared with 10-key.
2) Press [START] key.
The confirmation to clear is opened.
3) Select Yes/NO of counter clear with 10-key.
YES: Clear
NO: Not clear
4) Press [START] key.
1
DRUM ROTATION
2
DV ROTATION
1
1
Developer
OPC drum rotation time
DV unit rotation time

Hide quick links: