Sharp AR-M355U Service Manual page 126

Digital multifunctional system
Hide thumbs Also See for AR-M355U:
Table of Contents

Advertisement

<Specification>
Specification
Distance between
3-point contact
dove (Reference
(Left front/Left rear/Right
plate) and table
front when viewed from
glass
the front)
<3> SPF scan distortion adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
• SPF height adjustment
Items which must be executed after completion of this adjust-
ment.
• SPF off-center
• SPF lead edge adjustment
• Front/rear and left/right void amount setting
1) Make a test chart as shown below. (Print a self-print pattern
71.)
2) Make a copy with DSPF.
3) Check that it is in the specified range.
b
a
a
b
a
b
Adjustment
position
Hinge
adjustment set
screw
AR-M351U/M451U, AR-M355U/M455U ADJUSTMENTS 8 - 7
4) Execute SIM51-2 to check the SPF set value.
Change the set value of the SPF resist amount to the following
value.
7
SPF (HIGH)
8
SPF (LOW)
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-8, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.TRAY1
60
3.TRAY2
5.BPT
55
6.ADU
7.SPF(HIGH)
60
8.SPF(LOW)
5) Though the SPF resist amount is the above value, if there is
any distortion in SPF scan, adjust the SPF installing position in
the following procedures.
6) Loosen the nut which is fixing the adjustment set screw of the
hinge R, and adjust the adjustment set screw.
7) Make a copy again, and check again that the value is in the
specified range.
8) Tighten the nut to fix the adjustment screw.
b
a
<Specification>
Specification
Skew feed
Within ±3mm
After the SPF distortion adjustment, perform SIM53-8 SPF
scanning position automatic adjustment.
<4> OC scan magnification ratio adjustment
Items which must have been completed before this adjust-
ment.
• Adjustment on the engine side (If there is no problem in self
print, no need to adjust.)
• OC scan distortion adjustment
Items which must be executed after completion of this adjust-
ment.
• OC scan lead edge adjustment
• Original off-center adjustment
1) Place a print of self-print pattern (A3 or WLT) 70 or a scale on
the table glass.
2) Close the original cover, and make a copy.
3) Check that the value is within the specification.
4) If the value is not within the specified range, execute SIM48-1
(item 3, 4).
5) Make a copy again and check again that the value is within the
specification.
60
75
50
4.DESK
50
1
50
75
b
a
Adjustment position
Hinge R adjustment screw

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m455uAr-m351uAr-m451uAr-m351nAr-m451n

Table of Contents