: Feb. 6 2004
1
11. Power section
A. Maintenance and parts replacement
(1) Maintenance and parts replacement
(Replacement parts)
No.
Unit
a
a-6
a-7
a-5
a-1. AC power PWB
1) Remove the rear cabinet.
1
2) Disconnect the connector, and remove the AC power PWB.
Parts
1
AC power PWB
2
DC main power PWB
3
Power cooling fan motor 1
4
Power cooling fan motor 2
5
Dehumidifier heater relay PWB
6
DC sub power PWB
7
High voltage PWB (MC/DV/TC)
a-2
a-1
a-3
a-4
AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 151
a-2. DC main power PWB
(Method 1)
1
1) Remove the rear cabinet. (See "a-1. AC power PWB" in this sec-
tion)
2) Disconnect the connector and remove the harness clamp. Remove
1
the AC power PWB unit.
3) Disconnect the connector and remove the DC main power PWB.
1
(Method 2)
1
1) Remove the rear cabinet. (See "a-1. AC power PWB" in this sec-
tion)
2) Disconnect the connector.