Yaesu VX-8DE Operating Manual page 158

50/144/430 mhz triple-band heavy duty sumersible transceiver
Hide thumbs Also See for VX-8DE:
Table of Contents

Advertisement

S
M
ET
ODE
S
M
I
83: SCAN RESUME
Function: Selects the Scan Resume mode.
Available Values: 2.0sec ~ 10.0sec (0.5sec/step) /BUSY / HOLD
Default: 5.0sec
2.0sec - 10.0sec: The scanner will halt on a signal it encounters, and will hold there for
the selected resume time. If you do not take action to disable the scanner
within that time period, the scanner will resume even if the station is still
active.
BUSY:
The scanner will halt on a signal it encounters. When the signal drops,
the scanner will resume. The Scan resume time (default 2 seconds) is
controlled set by the Set Mode Item 82: SCAN RE-START.
HOLD:
The scanner will halt on a signal it encounters. It will not restart auto-
matically; you must manually re-initiate scanning if you wish to resume.
S
M
I
84: SENSOR DISPLAY
Function: Selects the sensor information when the transceiver is operating in the "Mono"
band mode with large characters.
Available Values: DC / TEMP / WAVE / BARO / ALTI / OFF
Default: DC
DC:
Indicates the battery voltage and battery type.
TEMP: Indicates the current temperature inside the transceiver's case.
WAVE: Depicts the (RX and TX) audio wave-form.
BARO: Indicates the Barometric Pressure and relative changes in the pressure (two bars
per hour).
ALTI: Indicates the Altitude.
OFF:
Disables the sensor information (Indicates the "Current Time" only).
S
M
I
85: SENSOR INFORMATION
Function: Indicates the information of the internal sensors.
S
M
I
86: SET MODE CSR
Function: Selects the Set Mode Cursor.
Available Values: nine patterns (
Default:
S
M
I
87: SET MODE FORMAT
Function: Selects the display format of the Set Mode operation.
Available Values: LIST / ITEM
Default: LIST
156
S
M
S
/
/
D
/
/
/
/
VX-8DR/DE O
/
/
)
M

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vx-8dr

Table of Contents