Maintenance and Troubleshooting
4.4

Resetting the Inverter

Under some fault conditions (i.e., an 'internal' fault), the inverter will need to be reset.
To reset the inverter:
Press and hold the Power ON/OFF pushbutton (see fi gure 4-1) for approximately fi fteen (15)
seconds until the Charging/Inverting Status LED comes on and fl ashes rapidly; once the rapid
fl ashing has begun, release the Power ON/OFF pushbutton. The Status LED will go off after the
pushbutton is released.
After the inverter reset is completed, press the ON/OFF pushbutton to turn the inverter ON.
Info: The Power ON/OFF pushbutton is a small momentary type switch which operates
by lightly pressing and releasing.
Page 48

Figure 4-1, Performing an Inverter Reset