Operation; Inverter Mode; Figure 3-1, Power Flow - Inverter Mode - Magnum Energy MS Series Owner's Manual

Ms series pure sine wave inverter/charger
Hide thumbs Also See for MS Series:
Table of Contents

Advertisement

3.0 Operation

The MS Series inverter has two normal operating routines; 1. Inverter Mode, which powers your
loads using the batteries, and 2. Standby Mode, which transfers the incoming AC Power (i.e.,
utility power or a generator) to power your loads and uses this incoming power to recharge the
batteries. This inverter also includes an extensive protection circuitry to shut-down the inverter
under certain fault conditions.
3.1

Inverter Mode

When the MS Series is fi rst powered up, it defaults to the OFF mode.
power switch
(item 1 fi gure 1-1)
pressing this switch alternately turns the inverter OFF and ON.
Inverter OFF -
When the inverter is OFF,
loads and
the status
LED will be OFF. If AC power from an external source (Utility or Generator)
is connected and qualifi ed on the inverter's AC input, this AC input power will pass through the
inverter to power the AC loads. However, if this AC power is lost, the AC loads will no longer be
powered because the inverter is OFF.
When the inverter is turned ON, it operates either by "Searching" or "Inverting", depending on
the connected AC loads.
Searching - When the inverter is fi rst turned ON, the automatic Search feature is enabled. This
feature is provided to conserve battery power when AC power is not required. In this mode,
the inverter pulses the AC output looking for an AC load (i.e., electrical appliance). Whenever
an AC load (greater than 5 watts) is turned on, the inverter recognizes the need for power and
automatically starts inverting. When there is no load (or less than 5 watts) detected, the inverter
automatically goes back into search mode to minimize energy consumption from the battery bank.
When the inverter is "Searching", the inverter's green LED fl ashes (fast).
Info: The factory default value for the Search feature is 5 watts, it can be turned off
or adjusted from 5 to 50 watts using the ME-RC remote display.
Inverting -
When a load greater than 5 watts is connected to the inverter output, the MS Series
"inverts" the DC power from the battery and supplies 120 VAC power to your sub-panel The
inverter's green LED fl ashes once every 2 seconds (medium fl ash) to indicate it is inverting. The
amount of time the inverter can be inverting and
of AC loads that are connected and the capacity of the battery bank. Refer to fi gure 3-1 to see
the fl ow of power from the DC input to the AC output while in the Inverter Mode.
A C H O T 2 IN
A C H O T 1 IN
A C N E U T R A L IN
A C G R O U N D
D C
D C N E G A T IV E
IN
D C P O S IT IV E
© 2009 Magnum Energy Inc.
must be lightly pressed to turn the inverter ON. Subsequently
no power is used from the batteries to power the AC
A C H ot
T rans fer R elay
C B 3 (3 0A )
A C
D C
F E T B ridge

Figure 3-1, Power Flow - Inverter Mode

provide power is directly related to the amount
C B2
( optional )
( optional )
N eutral -G round
T rans fer R elay
P ow er T rans form er
Installation
The momentary ON/OFF
IN V
O U T
A C H O T 2 O U T
A C H O T 1 O U T
C B1
A C N E U T R A L O U T
0
V A C
120
V A C
120
V A C
Page 39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnasine ms2012Magnasine ms2812Magnasine ms4024

Table of Contents