Yamaha O1V96 Owner's Manual page 48

Digital mixing console
Table of Contents

Advertisement

48
Chapter 5—Tutorial
Tip:
• See page 40 for more information on wordclock.
• See page 75 for more information on 01V96s running at higher sampling frequencies
(88.2 kHz or 96 kHz).
Note:
• You can select the 01V96 internal clock as the wordclock source. In this case, you must set
the hard disk recorder so that it will synchronize to an external clock.
• If the 01V96 and a connected device are not synching to each other, the 01V96 displays the
message "Sync Error!" If this happens, check the ADAT IN and OUT connections, digital
I/O card connection, and the sampling frequency setting on each device.
3 Press the DISPLAY ACCESS [PATCH] button repeatedly until the Patch | In
Patch page appears. On this page, make sure that the Input Patch settings
remain set to default values, as shown below.
By default (as shown in this example), the signals input at INPUT connectors 1–16 are
routed to Input Channels 1–16.
The signals input at the ADAT IN connector (the Track 1–8 signals from the hard disk
recorder in this example) are routed to Input Channels 17–24, and the signals input from
the slot (the Track 9–16 signals from the hard disk recorder) are routed to Input Channels
25–32.
If the Input Patch settings have been changed from the default settings, recall Input Patch
memory #00 from the Input Patch library (page 175).