5 When the calibration operation is complete, the 01V96 displays a window
in which you can select faders for position adjustment.
If you selected "2 FADER MOVE ONLY" in Step 3, the fader adjustment is complete. The
01V96 starts in normal mode.
6 Use the channel [SEL] buttons to select faders for which you wish to calibrate
the position, then press [ENTER].
The selected channel [SEL] button indicators flash. (When you press [ENTER], they light
up steadily.) At the beginning, all [SEL] buttons are flashing. However, if an error occurs
and the unit is trying calibration again, only the [SEL] button indicator of a problematic
fader flashes.
7 Follow the instruction in the window to set the position of the selected faders
to –∞, then press [ENTER].
8 Set the position of the selected faders to the level instructed in the window,
then press [ENTER]. Set faders 1-16 to –15, and Stereo fader to –30.
9 Set the position of the selected faders to the level instructed in the window,
then press [ENTER]. Set faders 1-16 to 0, and Stereo fader to any position.
10 Set the position of the selected faders to the level instructed in the window,
then press [ENTER]. Set faders 1-16 to +10, and Stereo fader to 0.
If there is no problem with the calibration result, this concludes the calibration operation.
The 01V96 will start in normal mode.
Calibrating the Faders
01V96 Version 2—Owner's Manual
245