Error Messages Displayed On The Panel; Figure 8.1 Fan Error Messages; Table 8.1 Fan Error Messages - Fujitsu PRIMEPOWER 1000 User Manual

Hide thumbs Also See for PRIMEPOWER 1000:
Table of Contents

Advertisement

8.4

Error Messages Displayed on the Panel

This section explains the error messages displayed in the operator panel if an abnormality is
detected in the main unit.
For operation of the operator panel, and other messages, see
Panel Operation."
While the fan symbol is selected (the cursor points to ), the following messages listed in
8.1
are displayed. If any defective fan is detected, the selected symbol ( ) blinks. If a defective
fan is not detected, no message will be displayed.
X -
Y Y
T H Z
P C
Display data
0#FANyy failed
0#FAN config err
*) PRIMEPOWER800 only has the value 0 for the first numeric value.
C120-E093-04EN
:
0#FANyy failed
S
0
1
Cursor position

Figure 8.1 Fan Error Messages

Table 8.1 Fan Error Messages

Contents
Indicates the defective fan. If
multiple defective fans were
detected, the unit last detected
is displayed.
Indicates a fan that has a
Configuration error.
8.4 Error Messages Displayed on the Panel
Chapter 5, "Main Unit Operator
Fan messages
2
3
4
5
6
7
8
Message details
First numerical value 0 (*):
One or more than one defective fan is detected
in the cabinet in which the panel is included (the
Base cabinet).
First numeric value 1:
One or more than one defective fan is detected
in the cabinet in which the panel is not included
(the System Expansion cabinet).
yy: Fan Tray number
First numerical value 0 (*):
One or more than one fan has a Configuration
error detected in the cabinet in which the panel
is included (the Base cabinet).
First numeric value 1:
One or more than one fan has a Configuration
error detected in the cabinet in which the panel
is not included (the System Expansion cabinet).