Installing The Tn2312Bp Ipsi Adapter; Approved Ground - Avaya G650 Installing

Avaya media gateway
Hide thumbs Also See for G650:
Table of Contents

Advertisement

Installing the TN2312BP IPSI adapter

Install the TN2312BP IPSI adapter on the connector panel in position 1 for carrier A. If you are using
duplicated IPSIs, connect another IPSI adapter in position 1 for carrier B. Connect the CAT 5 ethernet
cable to the adapter to connect the G650 to the ethernet.
the adapter.
If you want to use the external alarm function, attach an 9-pin external alarm cable to the TN2312BP IPSI
adapter. For the unterminated end, see the job aid titled Connector and Cable Diagrams (Pinout Charts)
(555-245-773).
Figure 9: G650 IPSI adapter

Approved ground

!
Installation in a Restricted Access Location and secure access are required in Finland and
Norway.
The G650 Media Gateway relies on two ground connections (main plug and an earth contact and a
permanent Supplementary Ground Conductor). Because of unreliable earthing concerns in Finland
and Norway, the G650 Media Gateway must be installed in a Restricted Access Location (RAL).
An RAL is defined as an access that can be gained only by trained service personnel or customers
who have been instructed about the reasons for the restricted access and any safety precautions that
must be taken. In these cases, access to the G650 Media Gateway is gained by the use of a tool
(such as a lock and key) or other means of security.
If you have any questions about the safety conditions, contact your Project Manager. When you
have verified that the site is ready for installation, proceed with the installation.
See the job aid titled Approved Grounds (555-245-772).
42
WARNING:
Figure 9, G650 IPSI adapter,
addpipsi LAO 081303
Installing the Avaya G650 Media Gateway
on page 42 shows
June 2004

Advertisement