Connecting The Audio, Sensor And Relay Device - Avermedia AVerDiGi EB3004 NET User Manual

Hide thumbs Also See for AVerDiGi EB3004 NET:
Table of Contents

Advertisement

1.4.3 Connecting the Audio, Sensor and Relay device

The Sensor, Alarm, and audio port enable you to connect 4 sensor inputs, 1 relay outputs, 4 audio in
devices and 1 audio out device. Just connect the external sensor, relay, and audio in/out device pin
directly to the pinhole. The RS485 port can be used for PTZ camera connection.
Check the table below and locate which pinhole is assigned to audio in/out, sensor input, and relay
output.
i
The RS232 port is not supported at this version.
The signal from the sensor (i.e., infrared sensors, smoke detectors, proximity sensors, door sensors,
etc.) is being transmitted to the unit and this triggers the system to respond and send signal to relay
device (i.e., alarm, telephone etc).
Audio in and out pinhole:
Sensor in and Alarm pinhole:
Pin #
1
Audio input signal
2
Audio Ground signal
3
Audio input signal
4
Audio Ground signal
5
Audio input signal
6
Audio Ground signal
7
Audio input signal
8
Audio Ground signal
9
Audio output signal
10
Audio Ground signal
Pin #
11
Sensor 1 signal
12
Sensor 1 Ground signal
13
Sensor 2 signal
14
Sensor 2 Ground signal
15
Sensor 3 signal
16
Sensor 3 Ground signal
17
Sensor 4 signal
18
Sensor 4 Ground signal
19
Relay signal
20
Relay signal
Definition
Definition