Upgrading library firmware

1
Follow the instructions in
LUN (Rnd or LUN).
2
Click the Firmware tab on the RMU main page.
3
Select Update Library Firmware.
4
Click Browse and browse to the location of the firmware update file.
Downloading firmware can take several minutes. For details on how long it
Note
takes to download firmware, click some time above the Update Firmware
button.
5
Click Update Firmware.
The firmware is updated and the RMU reboots.

Viewing Diagnostic Files

From the RMU, you can view the diagnostic information for the attached library and RMU. This information
can assist technical support personnel when they are diagnosing problems.
1
Click the Diagnostics file tab.
2
Select the file you would like to view. The available options are:
Library Command Log — Provides command logs for the library.
Library Error Log — Provides error logs for the library.
RMU Support Log — Provides support logs for the RMU.
RMU Error Log — Provides error logs for the RMU.
3
Click Retrieve selected file.
The file is loaded.
4
Click Display File to view the file in a separate browser window.

Rebooting the RMU

The RMU can be rebooted through the Configuration tab.
1
Log into the RMU.
2
Click the Configuration tab.
3
In the Reboot area, click the link to reboot the RMU.
The RMU reboots.

Rebooting the Library

The library can be rebooted through the Configuration tab.
1
Log into the RMU.
2
Click the Configuration tab.
3
In the Reboot area, click the link to reboot the library.
54
Configure Modes
on page 71 to set the library partition mode to random and
Using the Remote Management Unit