2 Procedure for copying the "Flat" correction curve set at "Auto Setup", then using the graphic equalizer to adjust
manually
NOTE: If the "Auto Setup" procedure has not been performed, this item is not displayed.
1
(Main unit)
(Remote control unit)
2
(Main unit)
(Remote control unit)
3
(Main unit)
CH SEL
ENTER
(Remote control unit)
(Remote control unit)
4
(Main unit)
(Remote control unit)
Select "Base Curve Copy".
CH SEL
ENTER
The Base Curve Select screen appears when the
Cursor left button is pressed.
CH SEL
ENTER
Select "Base Curve Copy?", then press the Cursor
left button to select "Yes".
(Main unit)
CH SEL
ENTER
Enter the setting.
The Manual EQ screen reappears.
CH SEL
ENTER
The type of the copied correction curve is displayed
in the upper right of this screen.
* M a n u a l E Q
B a s e C u r v e C o p y
* B a s e C u r v e
C o p y ? :
N o
* B a s e C u r v e
C o p y ? :
Y e s
79