68
Legend IP
User Manual

Macros page

You can program 32 macros per dome, which include six preprogrammed system macros to send e-mail. Each
macro can contain up to 16 steps. Each step can contain a preset, ShadowTour, relay action, jump command, or
macro command. These are the step types. The step type determines what additional features are available for
programming. Each macro can contain any number of the macro step types described.
Program page
Select a macro (1 through 32), and if no steps already exist, select Append to add the first step and make the
other programming features available.
To access the Program page of Macros, select Actions, Macros, and Program.
Figure 49. Program page
Note:
Remember to select OK to save any changes you make on the page.
No. The No. drop-down box allows you to select the macro number that you want to program. The Legend
IP comes with 6 preprogrammed macros (Table 9,
Table 9.
Preprogrammed macros
Macro no.
Video loss
Settings change
Video change
Menus accessed
Ethernet connection
Motor error
Action
An email is sent when a camera module failure is detected.
An email is sent when any camera setting is modified, except video encoder settings.
An email is sent when the video encoder settings are modified.
An email is sent when the GUI is activated.
An email is sent when one of the control ports is activated.
An email is sent when the motors stall due to an obstruction.
Preprogrammed
macros).