Macros page

You can program 32 macros per dome. Each macro can contain up to 16 steps. Each step can contain a preset,
ShadowTour, relay action, jump command, or macro command. These are the step types. The step type
determines what additional features are available for programming.
Program page
Select a macro (1 through 32), and if no steps already exist, select Append to add the first step and make the
other programming features available.
To access the Program page of Macros, select Actions, Macros, and Program.
Figure 32. Program page
Note:
Remember to select OK to save any changes you make on the page.
No. The No. drop-down box allows you to select the macro number that you want
to program.
Title. The Title box shows you the existing title for the selected macro number. You can customize the
default title on the Display page.
Macro list. The macro list (step, type, no., speed, zoom, and duration) shows the defined steps for the
macro in sequential order. You can use the buttons and drop-down boxes located below the summary
to add, delete, move up, or move down individual steps. The Append button adds steps.
Step. The Step box selects the step number you want to program. If no steps already exist, you must select
Append to add the first step and make the other programming features available.
Type. The Type box selects the action for the selected step. It determines what additional features appear
(are available) for programming. Choices are Preset (default), Tour, Macro, Relay, and Jump (jumps to
a prior step).