DC4 DC4 ESC A
Sets the horizontal spacing to 15, 17, 20, 24 CPI. (Compuprint)
ASCII Code
Hexadecimal Value
Decimal Value
This is terminator code and therefore causes the current contents of the print buffer to
be printed out. Then, the subsequent characters will be printed at the horizontal
spacing specified by the n parameter.
n
Spacing
4
15 cpi
5
17 cpi
6
20 cpi
7
24 cpi
DC4 DC4 ESC A n
14 14 1B 41 n
20 20 27 65 n