Use undo speed to restore the default transmission rate.
By default, the transmission rate is 9600 bps.
The transmission rate setting must be identical for the user interfaces of the connecting ports on the device
and the target terminal device for communication.
Examples
# Set the transmission rate on the AUX 0 user interface to 19200 bps.
<Sysname> system-view
[Sysname] user-interface aux 0
[Sysname-ui-aux0] speed 19200

stopbits

Syntax
stopbits { 1 | 1.5 | 2 }
undo stopbits
View
AUX user interface view
Default level
2: System level
Parameters
1: One stop bit.
1.5: One and a half stop bits.
2: Two stop bits.
Description
Use stopbits to set the number of stop bits transmitted per byte.
Use undo stopbits to restore the default.
By default, the stop bit is one.
The stop bits setting must be the identical for the user interfaces of the connecting ports on the device and
the target device for communication.
Examples
# Set the stop bits on the user interface AUX 0 to 1.5.
<Sysname> system-view
[Sysname] user-interface aux 0
[Sysname-ui-aux0] stopbits 1.5

telnet

Syntax
telnet remote-host [ service-port ] [ vpn-instance vpn-instance-name ] [ source { interface interface-type
interface-number | ip ip-address } ]
43