Syntax
screen-length screen-length
undo screen-length
View
User interface view
Default level
2: System level
Parameters
screen-length: Number of lines to be displayed on the screen, in the range of 0 to 512. The value of 0
disables pausing between screens of output.
Description
Use screen-length to set the number of lines to be displayed on the screen.
Use undo screen-length to restore the default.
By default, the screen displays 24 lines.
When screen output pauses, press the Space key to display the next screen. Not all terminals support this
command setting. For example, assume that you set screen-length to 40, but the terminal can display 24
lines in one screen at most. When you press Space, the device sends 40 lines to the terminal, but the next
screen displays only lines 18 through 40. To view the first 17 lines, you must press the page up or page
down key.
To disable multiple-screen output for the current user interface, use the screen-length disable command.
Examples
# Set the next screen of the AUX user interface 0 to display 30 lines.
<Sysname> system-view
[Sysname] user-interface aux 0
[Sysname-ui-aux0] screen-length 30

send

Syntax
send { all | num1 | { aux | vty } num2 }
View
User view
Default level
1: Monitor level
Parameters
all: Sends messages to all user interfaces.
aux: Specifies the AUX user interface.
vty: Specifies the VTY user interface.
num1: Absolute number of a user interface, in the range of 0 to 19.