Chapter 17 Remote Management
17.5.1 Supported MIBs
The P-793H v2 supports MIB II, which is defined in RFC-1213 and RFC-1215. The
focus of the MIBs is to let administrators collect statistical data and monitor status
and performance.
17.5.2 SNMP Traps
The P-793H v2 will send traps to the SNMP manager when any one of the
following events occurs:
Table 73 SNMP Traps
TRAP # TRAP NAME
0
1
4
6
6a
6b
246
coldStart (defined in RFC-
1215)
warmStart (defined in RFC-
1215)
authenticationFailure (defined
in RFC-1215)
whyReboot (defined in ZYXEL-
MIB)
For intentional reboot:
For fatal error:
DESCRIPTION
A trap is sent after booting (power on).
A trap is sent after booting (software reboot).
A trap is sent to the manager when receiving
any SNMP get or set requirements with the
wrong community (password).
A trap is sent with the reason of restart before
rebooting when the system is going to restart
(warm start).
A trap is sent with the message "System reboot
by user!" if reboot is done intentionally, (for
example, download new files, CI command "sys
reboot", etc.).
A trap is sent with the message of the fatal
code if the system reboots because of fatal
errors.
P-793H v2 User's Guide