Cisco MDS 9216 Hardware Installation Manual page 46

Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

32 Port Fibre Channel Advanced Services Module
Send documentation comments to mdsfeedback-doc@cisco.com.
Table 1-5
Fibre Channel Advanced Services Module Indicators
LED
Status
Status
Green
Orange
Red
Speed
On
Off
Link
Solid green
Steady flashing
green
Intermittent
flashing green
Solid orange
Flashing orange
Off
Cisco MDS 9216 Switch Hardware Installation Guide
1-20
For the detection of most component failures, each switching module has a
hardware watchdog timer that resets the card if is not serviced periodically.
Table 1-5
describes the LEDs for the Advanced Storage Services module.
Description
All diagnostics pass and the module is operational (normal
initialization sequence).
The module is booting or running diagnostics (normal
initialization sequence).
If the module is not booting or running diagnostics, an over
temperature condition has occurred (a minor threshold has been
exceeded during environmental monitoring).
The diagnostic test failed and the module is not operational
because a fault occurred during the initialization sequence.
If the module is not booting or running diagnostics, an over
temperature condition has occurred (a major threshold has been
exceeded during environmental monitoring).
Port is transmitting in 2-Gbps mode.
Port is transmitting in 1-Gbps mode.
Link is healthy.
Link is healthy and beacon is enabled.
Link is up and traffic is flowing through port.
Link is disabled by software.
A fault condition exists.
No link.
Chapter 1
Product Overview
78-16165-01

Advertisement

Table of Contents
loading

Table of Contents