Cisco MDS 9216 Hardware Installation Manual page 100

Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

Identifying Startup Problems
Send documentation comments to mdsfeedback-doc@cisco.com.
If any LEDs on the supervisor module or interface module front panel are red or
orange, contact your customer service representative (see the
Customer Service" section on page
For a complete description of the supervisor module and interface module LEDs,
see the
LEDs" section on page
Step 3
Verify that the Status LEDs on the supervisor module and on the switching or
services module are green when the supervisor module completes initialization.
This LED indicates that the modules are receiving power. It also indicates that the
module is recognized by the supervisor module, and that it contains a valid Flash
code version. This LED does not indicate the state of the individual interfaces on
the switching module. If a Status LED is red or orange, contact your customer
service representative (see the
page
Verify that the terminal is set correctly and that it is connected properly to the
Step 4
supervisor module console port if the boot information and system banner are not
displayed.
Cisco MDS 9216 Switch Hardware Installation Guide
A-4
The Active LED turns green, indicating that the supervisor module is
operational and active.
Each Link LED flashes orange once and stays orange during diagnostic boot
tests, and turns green when the module is operational (online). If no signal is
detected, the Link LED turns off. The Link LED blinks orange if the port is
bad.
"Supervisor Module LEDs" section on page 1-7
1-9.
A-7).
A-7).
"Contacting Customer Service" section on
Appendix A
Troubleshooting
"Contacting
and the
"Interface Module
78-16165-01