Monitoring The Power Injector Leds; Using The Reset Button - Cisco Aironet 1550 Installation Manual

Outdoor mesh access point
Hide thumbs Also See for Aironet 1550:
Table of Contents

Advertisement

Chapter 3
Troubleshooting

Monitoring the Power Injector LEDs

You can use the power injector LEDs to check the power injector status. The LEDs provide the following
status information:

Using the Reset Button

The access point has a reset button located on the bottom of the unit (see
reset button is recessed in a small hole that is sealed with a screw and a rubber gasket. The reset button
can be used to perform these functions:
Figure 3-5
1
OL-24247-01
AP POWER—Turns solid green after successful discovery; indicates that power injector is
supplying power to the access point.
FAULT—Turns solid red when a fault occurs during discovery mode or power-up. Check Ethernet
cables and connections before contacting your support organization for assistance.
AC POWER—Turns solid green when power injector is receiving AC power and is ready to provide
power to the access point.
Reset the access point—Press the reset button for less than 10 seconds.
Disable battery backup power—Press the reset button for more than 10 seconds.
Reset Button Location - Models AIR-CAP1552E-x-K9 and AIR-CAP1552EU-x-K9