Mounting the Access Point
Screw a M8 x16 bolt in the top support bolt hole on each side the access point (see
Step 7
screw the bolt all the way in; leave approximately a 0.25 inch (0.635 cm) space.
Figure 2-22
1
M8 x16 bolt (supplied with pole mount kit)
2
M8 x16 bolt (supplied with pole mount kit)
Step 8
Position the two bolts on the access point into the appropriate quick mount notches on each side of the
mounting bracket (see
Step 9
Screw a M8 x16 bolt (with flat and lock washers) into the second bolt hole on each side of the access
point.
Ensure that the front of the access point is vertical, and tighten the four bolts to 13 to 15 ft lbs
Step 10
(17.6 to 20.3 Nm).
For the 1552CU access point, continue with
Step 11
continue with
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
2-32
Position of 1552C or 1552CU Access Point in Pole Mount Bracket
1
2
Figure
2-22). Ensure that the hinged door is facing out.
Connecting a Cable POC Power to the Access Point, page
3
3
F-connector
Installing Antennas, page
2-36. For the 1552C access point,
Chapter 2
Installing the Access Point
Figure
2-22). Do not
2-58.
OL-24247-01