Cisco Aironet 1550 Installation Manual page 98

Outdoor mesh access point
Hide thumbs Also See for Aironet 1550:
Table of Contents

Advertisement

Powering the Access Point
For your safety, when connecting the access point AC power connector, always connect the access point
Caution
end of the cable FIRST. When removing the AC power connector, always disconnect the access point
end of the cable LAST.
If your access point contains a backup battery pack, you must press the reset button for 10 seconds or
more (see the
When using the streetlight power tap adapter (AIR-PWR-ST-LT-R3P=), ensure that the access point is
Step 3
mounted within 3 feet (1 m) of the outdoor light control. For mounting instructions, refer to the
"Installing the Mounting Bracket on a Pole (All Models)" section on page
Step 4
Ensure that a 6-AWG ground wire is attached to the access point (see
streetlight pole (for instructions see
Figure 2-38
1
Outdoor light control
2
Streetlight power tap adapter
Ensure that the streetlight power tap adapter, which uses a 3-pronged LC-10 twist-lock adapter, is placed
Step 5
between the outdoor light control and its fixture (refer to
designed to be used with LC-10 listed outdoor light controls operating at 100 to 480 VAC, 50 to 60 Hz.
Disconnect the outdoor light control from its fixture.
Step 6
Verify that the voltage available at the fixture is between 100 and 480 VAC, 50 to 60 Hz.
Step 7
Turn off power to the fixture at the designated circuits.
Step 8
When installing the streetlight power tap adapter to the access point AC power connector, always
Caution
connect the access point end of the cable FIRST. When removing the streetlight power tap adapter,
always disconnect the access point end of the cable LAST.
Note
Cisco Aironet 1550 Series Outdoor Mesh Access Point Hardware Installation Guide
2-52
"Disabling Backup Battery Power" section on page
Using the Streetlight Power Tap Adapter
1
2
Ensure that your antennas are connected to the access point before you apply power to the access
point.
Grounding the Access Point, page
3
3
6-AWG copper grounding wire
Figure
Chapter 2
Installing the Access Point
3-10.)
2-18.
Figure
2-38) and connected to the
2-41).