Configuring the Access Point

Figure 2-46
1
Insert the cable stinger connector pin into the cable POC connector opening in the access point case.
Step 7
Screw the F-connector adapter into the POC connector opening, and hand-tighten.
Step 8
Use an adjustable wrench to tighten the F-connector adapter to 6 to 7 ft lbs (8.1 to 9.5 Nm).
Step 9
Use a Phillips screw driver to tighten the F-connector adapter pin capture screw on the RF splitter to 5.5
Step 10
to 6.0 in. lbs (0.62 to 0.67 Nm).
Before connecting cable POC power to the access point, ensure that the antennas are attached to the
Step 11
access point.
Connect or attach the cable company POC cable to the F-connector adapter according to their
Step 12
specifications.
Turn on cable POC power.
Step 13
Reinsert the RF splitter shunt.
Step 14
Check the cable modem Power and Cable LEDs and verify that the cable modem receives power and
Step 15
registers to the cable network.
The Power LED (fifth LED from the hinge) is green to indicate power is available.The Cable LED
(second LED from the hinge) should be blinking green to indicate scanning the cable network and green
to indicate registered on the cable network.
Replace the ATTN and SHUNT connector plugs on the top of the access point and tighten to 6 to 7 ft lbs
Step 16
(8.1 to 9.5 Nm).
Configuring the Access Point

Adding the Access Point MAC Addresses to the Controller Filter List

Before installing your access points, configure your controller by adding the MAC addresses of the
access points to the filter list. MAC address filtering is enabled by default. This enables the controller to
respond to the listed access points. To add a MAC filter entry on the controller, follow these steps:
Step 1
Log into your controller using a web browser.